Danh mục sản phẩm Brooks Instrument

100% USA Origin Brooks Instrument Vietnam Recalibration Model 5853S/BE2BA3BB2BA1B1
For Flow rate between 100-200 slpm N2 Equivalent
Action : Only recalibration.
Extra charges if repair required.
100% USA Origin Brooks Instrument Vietnam Recalibration Model 5851S/BD2BA1BB2BA1B1
Action : Only recalibration.
Extra charges if repair required
100% USA Origin Brooks Vietnam SLA5853 Thermal Mass Flow Controller
Model: SLA5853SZXXXX
Flow Meter, Body 3
Digital I/O. Communications  Smart Emulation (Analog and/or RS485)
Mechanical Connections  10mm Tube Compression
O-ring Material  Viton
Valve Seat Material  Viton
Valve Type  Normally Closed (Press Diff > 2 bar)
Analog I/O  0-5 VDC
Power Supply  +24 Vdc
Output Enhancement  Standard Setting / Response Time
Certification  Standard Location (Safe Area)
Customer Process
Fluid                                                    : Air
Normal Upstream Pressure                : 7 bar-a
Normal Downstream Pressure            : 1-5 bar-g
Meter Specifications
Meter Flow (Full Scale)                     : 400 ln/min
Reference Temp                               : 0 degC
Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating                         : 70 bar-g
Max Temperature                              : 65 °C
Note: Spec reference to T88253/009.
(Mass flow contronllers and metters
BROOKS INSTRUMENT 6718WX - THE NETHERLANDS
SN/Year: T88253/009     2008
Modelnumber:  5853SBZ1039
I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA
OP - Press: pa = 7 Bar
Range/ fluid: 0 - 400 ln/min Air
DN 10
Limit PS 70 barg@TS: 21 độ C  PT 105
barg@TS: 21 độ C)
100% USA Origin Brooks Instrument Vietnam Brooks SLA5850 Thermal Mass Flow Controller
Model Code : SLA5850SB1DD1B2A1
SLA5850S Flow Controller, Body 0
Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
Mechanical Connections B1 1/4” Tube Compression w/Filter
O-ring Material D Kalrez
Valve Seat Material D Kalrez
Valve Type 1 Normally Closed
Analog I/O B 0-5 VDC
Power Supply 2 +24 Vdc
Output Enhancement A Standard Setting / Response Time
Certification 1 Standard Location (Safe Area)
(MFC 1: 5850S/BC1GA0AAACA1B1
Flowrate (30 ml – 3000ml/min)  for wet gas(10% wt SO2 +N2 balance).
Ope. Pressure max: ? (avoid SO2 condensate to liquid) if condition at Temp: 35°C and the flow: wet gas(10% wt SO2 +N2 balance)
Output signal: 0..5 Vdc with RS232 interface
Setpoint signal: 0…5 Vdc or 0..100% RS232
Connections: 1/4” OD Compression type (male)
Seals: Kalrez 6375)
100% USA Origin Brooks Vietnam SLA5860 Thermal Mass Flow Meter
Model Code : SLA5860SB1DA0B2A1
SLA5860S Flow Meter, Body 0
Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
Mechanical Connections B1 1/4” Tube Compression w/Filter
O-ring Material D Kalrez
Valve Seat Material A None
Valve Type 0 None
Analog I/O B 0-5 VDC
Power Supply 2 +24 Vdc
Output Enhancement A Standard Setting / Response Time
Certification 1 Standard Location (Safe Area)
Customer Process
Fluid: 10% SO2, 5% Water vapor, 85% N2 (percentage in mass)
Normal Upstream Pressure: 60-150 psig
Normal Downstream Pressure: 0-110 psig
Operating temperature : 65 degC
Meter Specifications
Meter Flow (Full Scale): 3000 mlst/min
Reference Temp: 70 degF
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating: 100 bar-g
Max Temperature: 65 °C
NOTE: Operating temp cannot exceed 65 degC
(MFM 1: 5860S/BC1GA0AACA1B1
Request: Need to measure correctly (30 ml – 3000ml/min)  for wet gas (10% wt SO2 + 5% steam +N2 balance).
Flow range: 0…3 ln/min for wet gas(10% wt SO2 + 5% steam +N2 balance)
Inlet pressure: max. 150 psig @ 70°C
max.  60 psig  @ 35°C
Outlet pressure: 0…110 psig  @ 70°C
0 psig @ 35°C
Temperature: 35°C…70°C
Output signal: 0..5 Vdc with RS232 interface
Setpoint signal: 0…5 Vdc or 0..100% RS232
Connections: 1/4” OD Compression type (male)
Seals: Kalrez 6375)
100% USA Origin Brooks Instrument Vietnam Brooks SLA5860 Thermal Mass Flow Meter
Model Code : SLA5860SB1DA0B2A1
SLA5860S Flow Meter, Body 0
Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
Mechanical Connections B1 1/4” Tube Compression w/Filter
O-ring Material D Kalrez
Valve Seat Material A None
Valve Type 0 None
Analog I/O B 0-5 VDC
Power Supply 2 +24 Vdc
Output Enhancement A Standard Setting / Response Time
Certification 1 Standard Location (Safe Area)
Customer Process
Fluid : 10% CH4O (methanol), 10% Water vapor, 30% CO2, 50% H2 (percentage in mass)
Normal Upstream Pressure                : 1.5-10 bar-g
Operating temperature                       : 65 degC
Meter Specifications
Meter Flow (Full Scale)                     : 1000 mlst/min
Reference Temp                               : 70 degF
Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating                         : 100 bar-g
Max Temperature                              : 65 °C
NOTE: 1) Operating temp cannot exceed 65 degC.
2) Metal seals not available.
(MFM 2: 5860S/BC1GA0AACA1B1
Flow: 20…1000 ml/min for wet gas (10% wt MeOH vapour  +10% steam +30%CO2 50%H2).
Inlet pressure:. 1.5 barg….10 barg
Temperature: 35°C…80°C
Output signal: 0..5 Vdc with RS232 interface
Setpoint signal: 0…5 Vdc or 0..100% RS232
Connections: 1/4” OD Compression type (male)
Seals: Metal)
100% USA Origin Brooks Vietnam SLA5853 Thermal Mass Flow Controller
Model: SLA5853SZXXXX
Flow Meter, Body 3
Digital I/O. Communications  Smart Emulation (Analog and/or RS485)
Mechanical Connections  10mm Tube Compression
O-ring Material  Viton
Valve Seat Material  Viton
Valve Type  Normally Closed (Press Diff > 2 bar)
Analog I/O  0-5 VDC
Power Supply  +24 Vdc
Output Enhancement  Standard Setting / Response Time
Certification  Standard Location (Safe Area)
Customer Process
Fluid                                                    : Air
Normal Upstream Pressure                : 7 bar-a
Normal Downstream Pressure            : 1-5 bar-g
Meter Specifications
Meter Flow (Full Scale)                     : 400 ln/min
Reference Temp                               : 0 degC
Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating                         : 70 bar-g
Max Temperature                              : 65 °C
Note: Spec reference to T88253/009.
(Mass flow contronllers and metters
BROOKS INSTRUMENT 6718WX - THE NETHERLANDS
SN/Year: T88253/009     2008
Modelnumber:  5853SBZ1039
I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA
OP - Press: pa = 7 Bar
Range/ fluid: 0 - 400 ln/min Air
DN 10
Limit PS 70 barg@TS: 21 độ C  PT 105
barg@TS: 21 độ C)
100% USA Origin Brooks Instrument Vietnam Brooks Model 2500 Series Flowmeters
Code: 2530A4A68SNVT
2530 Acrylic Flowmeter
Revision A: Revision A
Tube Tube 4A68: 2-20 SCFM Air
Fittings S: Stainless Steel
Valve N: No Valve
Seals VT: Viton
100% USA Origin Brooks Vietnam Brooks Oval Flowmeters
Replaced by: BM04
Code: BM04ASSF2H1CKAA
(Brooks Oval Flowmeters, BM Oval Series, Models BM04 Through BM50 ®
Code: BM04ASSN2N1ARAA)
100% USA Origin Brooks Vietnam SLAMF63 Thermal Mass Flow Meter
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485)
Mechanical Connections 3A: DIN DN15 PN40
O-ring Material B: Buna
Valve Seat Material A: None (Meter)
Valve Type 0: None
Analog I/O G: 4-20mA I/O (PG11 Cable Gland)
Power Supply 2: +24 Vdc
Output Enhancement A: Standard Setting / Response Time
Certification 1: Standard Location (Safe Area)
Valve Orifice Size: A No Orifice
Mass Flow Restrictor Type 5: LFE
Flow Restrictor Size D: Size D
Calibration conditions 1: Single S-series calibration
OEM Code A: Standard Brooks Label
Software Revision A: Revision A
Mounting Attitute 1: Horizontal base down
Baudrate F: 19200
Customer Process:
Fluid: CO2
Normal Upstream Pressure: 18 bar-g
Meter Specifications:
Meter Flow (Full Scale): 40 kg/hr
Reference Temp : 21.1 degC
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Ratin: 70 bar-g
Max Temperature: 65 °C
Ingress Protection: IP66
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66
Note: IP 66 tot hon IP65
(SLA5863S3ABA0C2A1A5D1AA
IP65)
100% USA Origin Brooks Instrument Vietnam Model Code: SLA5853S2CAB2B2A1
SLA5853 Mass Flow Controller
Digital I/O, Communication S: Smart Emulation (analog or RS-485)
Mechanical Connection 2C: 3/8” Compression
O-ring material A: Viton
Valve Seat material B: Viton
Valve Type 2: Normally Close
Analog I/O B: 0-5 Volt
Power Supply 2: +24 Vdc
Output Enhancement A: Standard Setting / Response time
Certification 1: Standard Location
* Customer Process Data:
Fluid: Air
Upstream Pressure: 5-10 kg/cm2-g
Downstream Pressure:  Customer to advice
* Meter Specifications:
Meter Range (Full Scale): 500 slpm
Ref Temperature: 70 degF
Accuracy: +/- 1% Rate
Max Pressure Rating: 100 bar g
Max Temperature: 65 °C
NOTE: Please confirm whether it is ln/min, lst/min or la/min that you need.
(Brooks Instrument mass flow controller for nitrogen and air.
- Flow rate: 0 - 500 lit/minute
- Compress air about 5 - 10 kg/cm2
- I/O digital signal can controlled by computer.
- Material for flow meter is metal)
100% USA Origin Brooks Vietnam SLAMF63 Thermal Mass Flow Meter
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485)
Mechanical Connections 3A: DIN DN15 PN40
O-ring Material B: Buna
Valve Seat Material A: None (Meter)
Valve Type 0: None
Analog I/O G: 4-20mA I/O (PG11 Cable Gland)
Power Supply 2: +24 Vdc
Output Enhancement A: Standard Setting / Response Time
Certification 1: Standard Location (Safe Area)
Valve Orifice Size: A No Orifice
Mass Flow Restrictor Type 5: LFE
Flow Restrictor Size D: Size D
Calibration conditions 1: Single S-series calibration
OEM Code A: Standard Brooks Label
Software Revision A: Revision A
Mounting Attitute 1: Horizontal base down
Baudrate F: 19200
Customer Process:
Fluid: CO2
Normal Upstream Pressure: 18 bar-g
Meter Specifications:
Meter Flow (Full Scale): 40 kg/hr
Reference Temp : 21.1 degC
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Ratin: 70 bar-g
Max Temperature: 65 °C
Ingress Protection: IP66
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66
Note: IP 66 tot hon IP65
(SLA5863S3ABA0C2A1A5D1AA
IP65)
100% USA Origin Brooks Vietnam 0254 Read Out & Control
Code: 0254AA2B23A
Type Housing: Panel Mount Kit
Power Cord For Power Supply: European Power Cord For 220 VAC
Power Supply Output Voltage: + 24 VDC
Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set
Options: RS-232 cable, 3 meter, 9 pin Female “D”
OEM Code: Standard Brooks Labelling
100% USA Origin Brooks Vietnam 0254 Read Out & Control
Code: 0254AA2B23A
Type Housing: Panel Mount Kit
Power Cord For Power Supply: European Power Cord For 220 VAC
Power Supply Output Voltage: + 24 VDC
Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set
Options: RS-232 cable, 3 meter, 9 pin Female “D”
OEM Code: Standard Brooks Labelling
100% USA Origin Brooks Instrument Vietnam Brooks SLA5863 Thermal Mass Flow Meter
Model: SLA5863S3ABA0C2A1A5D1AA
(Model: SLA5863S3A0C2A1A5D1AA
SN : F13319-001
Gas : CO2
Flow rate : 0-40kg/h)
100% USA Origin Brooks Instrument Vietnam Brooks SLA5863 Thermal Mass Flow Meter
Model: SLA5863S3ABA0C2A1A5D1AA
(Model: SLA5863S3A0C2A1A5D1AA
SN : F13319-001
Gas : CO2
Flow rate : 0-40kg/h)
100% USA Origin Brooks Instrument Vietnam Replaced by: 1250A-D6041
Brooks Instrument Flowmeter
1250 Glass Tube Flow meter
1250A: Glass Tube Flow Meter With Horizontal Connections
Tube model: D6041 Glass float
Fluid Type:  Air
Unit of measurement:   CCM
End Block Material:  Stainless Steel
Valve Designation:  Needle Valve at inlet
O-ring material:  Viton
Fitting: 1/4" NPT-F
Note: 1510 model is discontinued. Replacement model is 1250. But flow range is not exactly same. I quoted 20-900 ccm Air. Next higher is 50-1200 ccm
(Model: 1510 with meet the below specifications
Pressure: 300psig up to 250oF max
Material : Glass 316SS
Connections: 1/4"NPT
Type of Fluid: Gas.
Flow range: 100-1000ccm
Line valve inlet)
100% USA Origin Brooks Vietnam 3809 Armored Flowmeter
3809/E12D1BEAEAA
Note:
·         We are assuming it is water for now.
Do find out the liquid density and viscosity and the flow range required.
·         This model we quoted comes with 4-20mA output transmitter.
·         We follow the code your sales engineer provided.
·         If signal output is not required, please confirm then price is much lower.
(Model: 3809E12D1)
100% USA Origin Brooks Instrument Vietnam 5850E Mass Flow Controller
Brooks Instrument
Model: 5850EC1BF3PB2A
S/N: 8611HCO23461/1

Danh mục sản phẩm Brooks Instrument

CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT

 VPĐD: 602/41E, Điện Biên Phủ, P.22, Q.Bình Thạnh, Tp.HCM

 Ðiện Thoại:  (028) 35121007                Fax: (028) 35121008

 Nhân viên kinh doanh: Phan Hoàng Long (Mr.)

 Email:  sale02@tmpvietnam.com        Tel:  0917 .543 .068

 VP tại Đức: Am Boscheler Berg 4a 52134 Herzogenrath

 Website: avantgarde-x.de

Thông tin bottom 2
Thông tin bottom 3

© 2017 Tangminhphat.com, all right reserved.

Thiết kế website www.webso.vn

Loading...

Back To Top