100% USA Origin Brooks Vietnam SLA5853 Thermal Mass Flow Controller
Model: SLA5853SZXXXX
Flow Meter, Body 3
Digital I/O. Communications  Smart Emulation (Analog and/or RS485)
Mechanical Connections  10mm Tube Compression
O-ring Material  Viton
Valve Seat Material  Viton
Valve Type  Normally Closed (Press Diff > 2 bar)
Analog I/O  0-5 VDC
Power Supply  +24 Vdc
Output Enhancement  Standard Setting / Response Time
Certification  Standard Location (Safe Area)
Customer Process
Fluid                                                    : Air
Normal Upstream Pressure                : 7 bar-a
Normal Downstream Pressure            : 1-5 bar-g
Meter Specifications
Meter Flow (Full Scale)                     : 400 ln/min
Reference Temp                               : 0 degC
Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating                         : 70 bar-g
Max Temperature                              : 65 °C
Note: Spec reference to T88253/009.
(Mass flow contronllers and metters
BROOKS INSTRUMENT 6718WX - THE NETHERLANDS
SN/Year: T88253/009     2008
Modelnumber:  5853SBZ1039
I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA
OP - Press: pa = 7 Bar
Range/ fluid: 0 - 400 ln/min Air
DN 10
Limit PS 70 barg@TS: 21 độ C  PT 105
barg@TS: 21 độ C)
100% USA Origin Brooks Instrument Vietnam Brooks SLA5850 Thermal Mass Flow Controller
Model Code : SLA5850SB1DD1B2A1
SLA5850S Flow Controller, Body 0
Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
Mechanical Connections B1 1/4” Tube Compression w/Filter
O-ring Material D Kalrez
Valve Seat Material D Kalrez
Valve Type 1 Normally Closed
Analog I/O B 0-5 VDC
Power Supply 2 +24 Vdc
Output Enhancement A Standard Setting / Response Time
Certification 1 Standard Location (Safe Area)
(MFC 1: 5850S/BC1GA0AAACA1B1
Flowrate (30 ml – 3000ml/min)  for wet gas(10% wt SO2 +N2 balance).
Ope. Pressure max: ? (avoid SO2 condensate to liquid) if condition at Temp: 35°C and the flow: wet gas(10% wt SO2 +N2 balance)
Output signal: 0..5 Vdc with RS232 interface
Setpoint signal: 0…5 Vdc or 0..100% RS232
Connections: 1/4” OD Compression type (male)
Seals: Kalrez 6375)
100% USA Origin Brooks Vietnam SLA5860 Thermal Mass Flow Meter
Model Code : SLA5860SB1DA0B2A1
SLA5860S Flow Meter, Body 0
Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
Mechanical Connections B1 1/4” Tube Compression w/Filter
O-ring Material D Kalrez
Valve Seat Material A None
Valve Type 0 None
Analog I/O B 0-5 VDC
Power Supply 2 +24 Vdc
Output Enhancement A Standard Setting / Response Time
Certification 1 Standard Location (Safe Area)
Customer Process
Fluid: 10% SO2, 5% Water vapor, 85% N2 (percentage in mass)
Normal Upstream Pressure: 60-150 psig
Normal Downstream Pressure: 0-110 psig
Operating temperature : 65 degC
Meter Specifications
Meter Flow (Full Scale): 3000 mlst/min
Reference Temp: 70 degF
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating: 100 bar-g
Max Temperature: 65 °C
NOTE: Operating temp cannot exceed 65 degC
(MFM 1: 5860S/BC1GA0AACA1B1
Request: Need to measure correctly (30 ml – 3000ml/min)  for wet gas (10% wt SO2 + 5% steam +N2 balance).
Flow range: 0…3 ln/min for wet gas(10% wt SO2 + 5% steam +N2 balance)
Inlet pressure: max. 150 psig @ 70°C
max.  60 psig  @ 35°C
Outlet pressure: 0…110 psig  @ 70°C
0 psig @ 35°C
Temperature: 35°C…70°C
Output signal: 0..5 Vdc with RS232 interface
Setpoint signal: 0…5 Vdc or 0..100% RS232
Connections: 1/4” OD Compression type (male)
Seals: Kalrez 6375)
100% USA Origin Brooks Instrument Vietnam Brooks SLA5860 Thermal Mass Flow Meter
Model Code : SLA5860SB1DA0B2A1
SLA5860S Flow Meter, Body 0
Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
Mechanical Connections B1 1/4” Tube Compression w/Filter
O-ring Material D Kalrez
Valve Seat Material A None
Valve Type 0 None
Analog I/O B 0-5 VDC
Power Supply 2 +24 Vdc
Output Enhancement A Standard Setting / Response Time
Certification 1 Standard Location (Safe Area)
Customer Process
Fluid : 10% CH4O (methanol), 10% Water vapor, 30% CO2, 50% H2 (percentage in mass)
Normal Upstream Pressure                : 1.5-10 bar-g
Operating temperature                       : 65 degC
Meter Specifications
Meter Flow (Full Scale)                     : 1000 mlst/min
Reference Temp                               : 70 degF
Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating                         : 100 bar-g
Max Temperature                              : 65 °C
NOTE: 1) Operating temp cannot exceed 65 degC.
2) Metal seals not available.
(MFM 2: 5860S/BC1GA0AACA1B1
Flow: 20…1000 ml/min for wet gas (10% wt MeOH vapour  +10% steam +30%CO2 50%H2).
Inlet pressure:. 1.5 barg….10 barg
Temperature: 35°C…80°C
Output signal: 0..5 Vdc with RS232 interface
Setpoint signal: 0…5 Vdc or 0..100% RS232
Connections: 1/4” OD Compression type (male)
Seals: Metal)
100% USA Origin Brooks Vietnam SLA5853 Thermal Mass Flow Controller
Model: SLA5853SZXXXX
Flow Meter, Body 3
Digital I/O. Communications  Smart Emulation (Analog and/or RS485)
Mechanical Connections  10mm Tube Compression
O-ring Material  Viton
Valve Seat Material  Viton
Valve Type  Normally Closed (Press Diff > 2 bar)
Analog I/O  0-5 VDC
Power Supply  +24 Vdc
Output Enhancement  Standard Setting / Response Time
Certification  Standard Location (Safe Area)
Customer Process
Fluid                                                    : Air
Normal Upstream Pressure                : 7 bar-a
Normal Downstream Pressure            : 1-5 bar-g
Meter Specifications
Meter Flow (Full Scale)                     : 400 ln/min
Reference Temp                               : 0 degC
Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Rating                         : 70 bar-g
Max Temperature                              : 65 °C
Note: Spec reference to T88253/009.
(Mass flow contronllers and metters
BROOKS INSTRUMENT 6718WX - THE NETHERLANDS
SN/Year: T88253/009     2008
Modelnumber:  5853SBZ1039
I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA
OP - Press: pa = 7 Bar
Range/ fluid: 0 - 400 ln/min Air
DN 10
Limit PS 70 barg@TS: 21 độ C  PT 105
barg@TS: 21 độ C)
100% USA Origin Brooks Instrument Vietnam Brooks Model 2500 Series Flowmeters
Code: 2530A4A68SNVT
2530 Acrylic Flowmeter
Revision A: Revision A
Tube Tube 4A68: 2-20 SCFM Air
Fittings S: Stainless Steel
Valve N: No Valve
Seals VT: Viton
100% USA Origin Brooks Vietnam Brooks Oval Flowmeters
Replaced by: BM04
Code: BM04ASSF2H1CKAA
(Brooks Oval Flowmeters, BM Oval Series, Models BM04 Through BM50 ®
Code: BM04ASSN2N1ARAA)
100% USA Origin Brooks Vietnam SLAMF63 Thermal Mass Flow Meter
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485)
Mechanical Connections 3A: DIN DN15 PN40
O-ring Material B: Buna
Valve Seat Material A: None (Meter)
Valve Type 0: None
Analog I/O G: 4-20mA I/O (PG11 Cable Gland)
Power Supply 2: +24 Vdc
Output Enhancement A: Standard Setting / Response Time
Certification 1: Standard Location (Safe Area)
Valve Orifice Size: A No Orifice
Mass Flow Restrictor Type 5: LFE
Flow Restrictor Size D: Size D
Calibration conditions 1: Single S-series calibration
OEM Code A: Standard Brooks Label
Software Revision A: Revision A
Mounting Attitute 1: Horizontal base down
Baudrate F: 19200
Customer Process:
Fluid: CO2
Normal Upstream Pressure: 18 bar-g
Meter Specifications:
Meter Flow (Full Scale): 40 kg/hr
Reference Temp : 21.1 degC
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Ratin: 70 bar-g
Max Temperature: 65 °C
Ingress Protection: IP66
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66
Note: IP 66 tot hon IP65
(SLA5863S3ABA0C2A1A5D1AA
IP65)
100% USA Origin Brooks Instrument Vietnam Model Code: SLA5853S2CAB2B2A1
SLA5853 Mass Flow Controller
Digital I/O, Communication S: Smart Emulation (analog or RS-485)
Mechanical Connection 2C: 3/8” Compression
O-ring material A: Viton
Valve Seat material B: Viton
Valve Type 2: Normally Close
Analog I/O B: 0-5 Volt
Power Supply 2: +24 Vdc
Output Enhancement A: Standard Setting / Response time
Certification 1: Standard Location
* Customer Process Data:
Fluid: Air
Upstream Pressure: 5-10 kg/cm2-g
Downstream Pressure:  Customer to advice
* Meter Specifications:
Meter Range (Full Scale): 500 slpm
Ref Temperature: 70 degF
Accuracy: +/- 1% Rate
Max Pressure Rating: 100 bar g
Max Temperature: 65 °C
NOTE: Please confirm whether it is ln/min, lst/min or la/min that you need.
(Brooks Instrument mass flow controller for nitrogen and air.
- Flow rate: 0 - 500 lit/minute
- Compress air about 5 - 10 kg/cm2
- I/O digital signal can controlled by computer.
- Material for flow meter is metal)
100% USA Origin Brooks Vietnam SLAMF63 Thermal Mass Flow Meter
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485)
Mechanical Connections 3A: DIN DN15 PN40
O-ring Material B: Buna
Valve Seat Material A: None (Meter)
Valve Type 0: None
Analog I/O G: 4-20mA I/O (PG11 Cable Gland)
Power Supply 2: +24 Vdc
Output Enhancement A: Standard Setting / Response Time
Certification 1: Standard Location (Safe Area)
Valve Orifice Size: A No Orifice
Mass Flow Restrictor Type 5: LFE
Flow Restrictor Size D: Size D
Calibration conditions 1: Single S-series calibration
OEM Code A: Standard Brooks Label
Software Revision A: Revision A
Mounting Attitute 1: Horizontal base down
Baudrate F: 19200
Customer Process:
Fluid: CO2
Normal Upstream Pressure: 18 bar-g
Meter Specifications:
Meter Flow (Full Scale): 40 kg/hr
Reference Temp : 21.1 degC
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
Max Pressure Ratin: 70 bar-g
Max Temperature: 65 °C
Ingress Protection: IP66
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66
Note: IP 66 tot hon IP65
(SLA5863S3ABA0C2A1A5D1AA
IP65)
100% USA Origin Brooks Vietnam 0254 Read Out & Control
Code: 0254AA2B23A
Type Housing: Panel Mount Kit
Power Cord For Power Supply: European Power Cord For 220 VAC
Power Supply Output Voltage: + 24 VDC
Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set
Options: RS-232 cable, 3 meter, 9 pin Female “D”
OEM Code: Standard Brooks Labelling
100% USA Origin Brooks Vietnam 0254 Read Out & Control
Code: 0254AA2B23A
Type Housing: Panel Mount Kit
Power Cord For Power Supply: European Power Cord For 220 VAC
Power Supply Output Voltage: + 24 VDC
Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set
Options: RS-232 cable, 3 meter, 9 pin Female “D”
OEM Code: Standard Brooks Labelling
100% USA Origin Brooks Instrument Vietnam Brooks SLA5863 Thermal Mass Flow Meter
Model: SLA5863S3ABA0C2A1A5D1AA
(Model: SLA5863S3A0C2A1A5D1AA
SN : F13319-001
Gas : CO2
Flow rate : 0-40kg/h)
100% USA Origin Brooks Instrument Vietnam Brooks SLA5863 Thermal Mass Flow Meter
Model: SLA5863S3ABA0C2A1A5D1AA
(Model: SLA5863S3A0C2A1A5D1AA
SN : F13319-001
Gas : CO2
Flow rate : 0-40kg/h)
100% USA Origin Brooks Instrument Vietnam Replaced by: 1250A-D6041
Brooks Instrument Flowmeter
1250 Glass Tube Flow meter
1250A: Glass Tube Flow Meter With Horizontal Connections
Tube model: D6041 Glass float
Fluid Type:  Air
Unit of measurement:   CCM
End Block Material:  Stainless Steel
Valve Designation:  Needle Valve at inlet
O-ring material:  Viton
Fitting: 1/4" NPT-F
Note: 1510 model is discontinued. Replacement model is 1250. But flow range is not exactly same. I quoted 20-900 ccm Air. Next higher is 50-1200 ccm
(Model: 1510 with meet the below specifications
Pressure: 300psig up to 250oF max
Material : Glass 316SS
Connections: 1/4"NPT
Type of Fluid: Gas.
Flow range: 100-1000ccm
Line valve inlet)
100% USA Origin Brooks Vietnam 3809 Armored Flowmeter
3809/E12D1BEAEAA
Note:
·         We are assuming it is water for now.
Do find out the liquid density and viscosity and the flow range required.
·         This model we quoted comes with 4-20mA output transmitter.
·         We follow the code your sales engineer provided.
·         If signal output is not required, please confirm then price is much lower.
(Model: 3809E12D1)
100% USA Origin Brooks Instrument Vietnam 5850E Mass Flow Controller
Brooks Instrument
Model: 5850EC1BF3PB2A
S/N: 8611HCO23461/1

Danh mục sản phẩm Brooks Instrument

Danh mục sản phẩmDanh mục sản phẩm
Hỗ trợ trực tuyến
Liên hệ tư vấn mua hàng
Dịch vụ của chúng tôi
Thống kê truy cập
  • Trực tuyến:
    2
  • Hôm nay:
    200
  • Tuần này:
    3420
  • Tháng trước:
    8816
  • Tất cả:
    1998160
Video ClipVideo Clip
CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT

 VPĐD: Số 1, Đường 27, Phường Hiệp Bình Chánh, Quận Thủ Đức, TP.HCM

 Ðiện Thoại:  (028) 35121007                Fax: (028) 35121008

 Nhân viên kinh doanh: Viet (Mr.)

 Email:  sale20@tmpvietnam.com        Tel:  0936 862 034

 VP tại Đức: Am Boscheler Berg 4a 52134 Herzogenrath

 Website: avantgarde-x.de

Thông tin bottom 2

Thông tin bottom 3

© 2017 Tangminhphat.com, all right reserved.

Thiết kế website www.webso.vn

Loading...

Back To Top