The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.
Benefits
-
High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
-
High degree of insert compatibility and design as per DIN 43772
-
Extension neck to protect the head transmitter from overheating
-
Fast response time with reduced/tapered tip form
-
Types of protection for use in hazardous locations: Intrinsic safety (Ex ia), non-sparking (Ex nA)
Measuring PrincipleThermocoupleCharacteristic / Applicationmetric style
modular temperature assembly
universal range of application
suitable for hazardous areas
threaded process connection
with neck
incl. thermowell / protection tube (metal)
Terminal headTA20A - aluminium - cover with screws
TA20B - plastics - screw cover
TA20D - aluminium - hinged cover high
TA20J - SS - deep-drawn w. or w/o. display
TA20R - SS - machined w. screw cover
TA20W - aluminium - cover w. snap fit
TA21E - aluminium - screw cover w. chain
TA30A - E+H, aluminium - cover low - w. or w/o. display
TA30D - E+H, aluminium - cover high
Thermowell / protection tubewelded protection tube
Insert / probemineral insulated (MI), flexible
Outer diameter protection tube9,0 mm (0,35')
11,0 mm (0,43')
12,0 mm (0,47')
Max. immersion length on requestup to 10.000,00 mm (393,70')
Material protection tube/ thermowell1.4404 (316L)
1.4571 (316Ti)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
Optional coatingNot defined
Process connectionmale thread:
G1/2"
G3/4"
G1"
NPT1/2"
NPT3/4"
M20x1.5
R1/2"
R3/4"
Tip shapestraight
reduced
tapered
Surface roughness Ra0,8 μm (31,5 μin.)
Operating temperature rangeType K:
-40 °C ...1.100 °C
(-40 °F ...2.012 °F)
Type J:
-40 °C ...750 °C)
(-40 °F ...1.382 °F)
Max. process pressure (static)at 20 °C: 75 bar (1088 psi)
Accuracyclass 1 acc. to IEC 60584
Response timedepending on configuration
t50 = 6 s
t90 = 13 s
Integration head transmitteryes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsATEX II
ATEX IECEx
NEPSI
IECEx
CertificationGost Metrology
SIL (transmitter only)
Cảm biến nhiệt độ Omnigrad M TC10 – Endress + Hauser Vietnam – TMP Vietnam
- AT2E
- Ametek
- Aira
- Bircher
- Bihl Wiedemann
- Barksdale
- Brooks Instrument
- Burkert
- Beckhoff
- BAUMULLER
- Bussmann
- Badger Meter
- Baumer
- BCS
- CEBA
- CS Instrument
- DWYER
- Euroswitch
- EBM Papst
- Elau Schneider
- Endress + Hauser
- ELETTROTEK KABEL
- Elco Holding
- Fotoelektrik Pauly
- Fireye
- Fairchild
- Fox Thermal
- Festo
- GINICE
- IPF ELECTRONIC
- IBA
- Indra
- Keller
- KIEPE ELEKTRIK
- Koganei
- KITZ
- Knick
- Land Ametek
- MARK-10
- Matsushima
- Matsui
- Masibus
- Mehrer
- Masoneilan
- Minimax
- Nireco
- Noshok.
- Novotechnik
- Nokeval
- Norgren
- Ohkura
- Pora
- PCI Instrument
- Red Lion
- Rotork
- Soldo
- Teclock
- Telco Sensor
- TDK Lambda
- Vibro-meter
- Wise control
- Weidmuller
- Young tech
- ZAMASENSOR
- Autrol
- Wago
- FineTek
- Riels
- Auma
- Gastron
- Dittmer
- JD Control
- Staubli
- Yamato
- Tempsen
- Schubert Salzer
- Wonil
- Phisher
- Precision Digital
- Moog
- Tek Trol
- Kometer
- Tema Vasconi
- Ceia
- Bronkhorst
- Krohne
- Comet
- Sitec
- ID Insert Deal
- Schneider Electric
- Proface
- Beijing Goda
- PFEIFFER Vacuum
- Okazaki
- DMN WestingHouse
- Kracht
- Sensy
- Hirose Valve
- REIVAX
- Endress Hauser
- CEMB
- Labom
-
Trực tuyến:5
-
Hôm nay:429
-
Tuần này:5073
-
Tháng trước:12161
-
Tất cả:1994417